Description
A Stainless Steel compression load cell suitable for weighing tanks or hoppers along with the KCPN Mounting Kit. Â Can also be used for force measurement.
TECHNICAL FEATURES
- Minimum load cell verification interval: Vmin = EMax / 10000
- Full Scale Output: 2mV/V +/- 0,5%
- Non-Repeatability: 0,01% F.S.
- Temperature effect on zero: 0,02% / 10°C
- Temperature effect on full scale output: 0,02% / 10°C
- Compensated Temperature Range: -10°C/+50°C
- Operating Temperature Range: -20°C/+60°C
- Creep error after 30 minutes: 0,02% F.S.
- Recommended excitation voltage: 10 Vdc
- Maximum tolerated excitation voltage: 15 Vdc
- Input Resistance: 750 ± 10 Ohm
- Output Resistance: 700 ± 5 Ohm
- Zero Balance: +/-1% F.S.
- Insulation Resistance: >5000 MOhm
- Safe Overload: 120% F.S.
- 4-wire shielded cable, 5 mm diameter:
- – 5 m long for CPX 250…5000 versions;
- – 10 m long for CPX 7500…100000 versions.

Example of CPX Compression Load Cell used with the KCPN mounting kit